Disconnection of the gas cylinder
Twist-on connection
Quick-release
1.
Turn off the GaLiO Insert – put it into the OFF position. The main and pilot burner need to be
turned off.
2.
Turn the bottle valve into the OFF position
(clockwise).
2.
Turn the switch into the OFF position.
3.
NEVER DO NOT unmount the regulator (or
connecting nut) when the bottle valve is
open.
4.
TAKE OFF the regulator (or the connecting
nut) with the use of a wrench or a
connecting knob.
3.
Take off the quick-release regulator by
pressing the switch horizontally and
simultaneously pulling the whole regulator
upwards.
5.
REPLACE the linkage closer or cap on the
empty or partially full bottle if it’s not being
used.
4.
REPLACE the tightening cap on an empty or
partially full bottle if it’s not being used.
5.3
Adapters for the gas cylinder connection (LPG version)
When the thread of the installed pressure regulator does not fit into the thread on the valve of the gas cylinder,