User’s Manual of WGSW-24040 / WGSW-24040R
Figure 2-11
Pull out the SFP transceiver
Never pull out the module without pull the handle or the push bolts on the module. Direct pull
out the module with violent could damage the module and SFP module slot of the Managed
Switch.
2.2.4 Connecting DC Power Supply – WGSW-24040R
The WGSW-24040R supports -48VDC power input, connect the power cable to the switch at the input terminal block.
1.
The size of the three screws in the terminal block is M3.5.
2.
The terminals are marked “V+”, “V-” & “FG“.
3.
Loosen the three screws so you can slide the DC cable beneath it. Insert the DC cable into the connector first, and screw
it down tight.
4.
Connect the power cable to the DC power supply. After power up or reset, the Managed Switch performs a cold start
procedure.
Figure 2-20
-48VDC connector
Warning:
Before connect the DC power cable to the input terminal block of Managed Switch, ensure that the
power switch in the “
OFF”
position and the DC power is
OFF
38