![Planet Networking & Communication MGSD-10080F User Manual Download Page 77](http://html.mh-extra.com/html/planet-networking-and-communication/mgsd-10080f/mgsd-10080f_user-manual_1563904077.webp)
User’s Manual of MGSW-MGSD Series
4.2.17 Faulty
Alarm
The Faulty Relay Alarm function provides the Power Failure and Port Link Down/Broken detection. With both power input 1 and
power input 2 installed and the check boxes of power 1/power 2 ticked, the FAULTY LED indicator will then be possible to light
up when any one of the power failures occurs. As for the Port Link Down/Broken detection, the FAULT LED indicator will light up
when the port failure occurs; certainly the check box beside the port must be ticked first. Please refer to the segment of ‘
Wiring
the Fault Alarm Contact
’ for the failure detection. The Configuration screen in
Figure 4-2-20
appears.
Figure 4-2-20
Windows File Selection Menu Popup
The page includes the following fields:
Object
Description
Allows user to enable Fault Alarm function.
Enable
Record
Allows user to record alarm message to System log, syslog or issues out via
SNMP Trap or SMTP.
As default SNMP Trap and SMTP are disabled, please enable them first if you
want to issue alarm message via them.
Allows user to monitor and alarm from port fail or power fail.
Action
Allows user to choose which power module want to be monitored.
Power Alarm
Allows user to choose which port want to be monitored.
Port Alarm
Buttons
: Click to save changes.
: Click to undo any changes made locally and revert to previously saved values.
77