![Planet Networking & Communication MGSD-10080F User Manual Download Page 48](http://html.mh-extra.com/html/planet-networking-and-communication/mgsd-10080f/mgsd-10080f_user-manual_1563904048.webp)
User’s Manual of MGSW-MGSD Series
48
4. WEB CONFIGURATION
This section introduces the configuration and functions of the Web-based management.
About Web-based Management
The
Managed Switch
offers management features that allow users to manage the
Managed Switch
from anywhere on the
network through a standard browser such as Microsoft Internet Explorer.
The Web-Based Management supports Internet Explorer 7.0. It is based on Java Applets with an aim to reduce network
bandwidth consumption, enhance access speed and present an easy viewing screen.
By default, IE7.0 or later version does not allow Java Applets to open sockets. The user has to
explicitly modify the browser setting to enable Java Applets to use network ports.
The
Managed Switch
can be configured through an Ethernet connection, making sure the manager PC must be set on the
same IP subnet address with the
Managed Switch
.
For example, the default IP address of the
Managed Switch
is
192.168.0.100
, then the manager PC should be set at
192.168.0.x
(where x is a number between 1 and 254, except 100), and the default subnet mask is 255.255.255.0.
If you have changed the default IP address of the
Managed Switch
to 192.168.1.1 with subnet mask 255.255.255.0 via console,
then the manager PC should be set at 192.168.1.x (where x is a number between 2 and 254) to do the relative configuration on
manager PC.
Figure 4-1-1:
Web Management