13.5
MAXIMUM CURRENT EXCEEDED ALARM
Vantage enters this state if the current running through the motor exceeds the maximum permiTed thre-
shold. The alarm is shown by the red LED, which flashes rapidly. This value can be exceeded for various
reasons such as dirt in the chamber or obstructions in the delivery line. This alarm is reset the next time
the pump is used.
13.6
MAXIMUM TEMPERATURE EXCEEDED ALARM
NOTICE
Vantage can reach temperatures of ~50/60°C.
The alarm is shown by the red LED, which flashes slowly. This value should only be exceeded
under extreme working conditions (for example, the simultaneous presence of a very hot
ambient temperature as well as a very heavy hydraulic load). This alarm is reset the next time
the pump is used.
14
MAINTENANCE
Vantage pumps are designed and manufactured to require minimum maintenance. Neverthe-
less, bear the following basic recommendations in mind for proper pump operation:
ONCE A WEEK:
- Check that the pipe connections are not loose to prevent any leaks;
- Check and keep the filter installed on the suction line clean.
ONCE A MONTH:
- Check the pump body and keep it clean and free of any impurities;
- Check that the electrical supply cables are in good condition.
ATTENTION
Do not put your fingers into the Vantage openings while the
pump is working.
15
NOISE LEVEL
In normal operating conditions, noise emissions of all models does not exceed 80dB at a distan-
ce of 1 metre from the electric pump.