39
/124
39
/60
EN
This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.
Translated from Italian
NOTICE
NOTICE: the system goes into standby mode by switching off all 3
LEDs 1 minute aer the end of the last operation.
Status Led
Status
green LED
Yellow LED
Red LED
Off
Off
Off
Stand-by phase
Flashing
Off
Off
Insufficient voltage alarm
On
Off
Off
Power is normally present
On
Off
On
Pump is ON
On
Off
Rapid Flashing
Rapid flashing: Maximum current
exceeded alarm
On
Off
Slow Flashing
Slow flashing: Maximum temperature
exceeded alarm
On
On
Off
Level alarm
On
Flashing
Off
Failure-to-prime alarm
- when dispensing begins (empty tubes)or
- when dispensing ends due to lack of
fluid
Flashing
Flashing
Off
Piloting fault of motor MOS n°1: contact
technical assistance ASAP
On
Flashing
Flashing
Piloting fault of motor MOS n°2: contact
technical assistance ASAP