34
3. Settings
ALWays 0 (ALW0)
This is an integrity check. If always 0 (zero) is defined in the OMR profile, the reader ex
-
pects a 0 (zero) in this position on every sheet. Anything else will be regarded as an integ-
rity error.
ALWays 1 (ALW1)
This is an integrity check. If always 1 (ONE) is defined in the OMR profile, the reader ex
-
pects a 1 (ONE) in this position on every sheet. Anything else will be regarded as an integ-
rity error.
Set Integrity (SI)
This is a set integrity check to verify that all sheets in a set carry the same SI value. For
the next set, the value must be different. How is not important, see example below.
Set
Sheet
SI value
1
1
111
1
2
111
1
3
111
2
4
000
3
5
100
3
6
100
Set SeQuence (SSQ)
This is a counter that checks that certain defined marks on each sheet follows in the right
order
within the set
. The difference, compared to WAS, is that the SSQ starts over for
each set.
The counter starts and stops at a value of your choice but increases by 1 (one) for every
sheet fed. After reaching the EOC mark (see below), the counter starts all over again at
the next set.
This continues throughout the whole feeding sequence no matter how many insertions that
are done.
Counting is binary and the reading direction must be specified since the result differs.
Binary code 100 read from left to right equals 1 (one).
Same binary code read from right to left equals 4 (four).
Summary of Contents for F65A
Page 1: ...Feeder Loader F65A B Operator Guide English Version ...
Page 2: ...2 ...
Page 6: ...6 ...
Page 10: ...10 ...
Page 40: ...40 5 General Remarks ...
Page 48: ...48 Notes ...
Page 49: ......