Six Head Open Fryer
Volume 2
Equipment, Cleaning, and Maintenance
June 10, 2002
Six Head Open Fryer – 33
L20-242 Rev 0 (7/02)
Problem
Possible Cause
Solution
Shortening has been added to
the fryer, and landed on
computer probe.
Stir shortening in tank using
clean out rod or by raising
and lowering the lift
assembly.
Computer
displays “HI”
and alarm
sounds
A component related to heat
control has failed
Turn off power to the fryer
and contact maintenance.
Incorrect product key settings.
See set points page 39.
Product
scorched or
burnt
Incorrect gas pressure.
Contact maintenance.
Shortening
will not drain
Solid shortening or cracklings
in drain line.
Clean drain line.
Shortening too old.
Discard shortening.
Excessive
foam or
smoking
Cooking temperature set too
high.
See set points info page 39.
Filter pan
does not
slide into the
fryer easily or
connect to
fryer properly
Movement of the fryer for
cleaning or service may
require adjustment of the fryer
legs.
Adjust moveable lower part
of fryer led to raise or lower
fryer until the filter slides
freely.