• Insert the flame broiler adjusting bar through the opening on the left
panel of the main barrel. Slide the notched end of the adjusting bar into
the raised tab on the flame broiler slider, giving you adjustable access to
the slider on the main plate. Note 24D.
NOTE: When the flame broiler slider is open, and direct flame is used
while cooking, do not leave the grill unattended for any period of time.
• Place the cooking grids, side-by-side, on the grid ledge inside the main
grill. Place the upper cooking rack on the upper ledge inside the main
grill. The cooking rack will lock into place. Note 24D.
IMPORTANT: To maintain optimal searing and grilling performance of
your cooking grids, regular care and maintenance is required.
25. PLACING THE GREASE BUCKET, GREASE TRAY
Parts Required:
1 x Grease Bucket
(#22)
1 x Grease Tray
(#25)
Installation:
• Unscrew the four screws along the outside of the hopper that secure
the hopper safety screen to the interior, and remove the safety screen
to access the grease bucket. Replace the hopper safety screen, and
re-install the four screws to secure. Note 25A.
• Slide the grease tray into the bottom of the barrel. Place the grease
bucket on the spout hook on the bottom of the main barrel. Ensure
both components are level to avoid grease spills. Note 25B.
26. INSTALLING THE IGNITER BATTERY
Parts Required:
1 x AA Battery
(#K)
Installation:
• Unscrew igniter cap from control panel. Insert battery into battery
slot with positive end (+) facing outward. Screw cap back onto panel.
• The unit is now completely assembled.
27. CONNECTING TO A POWER SOURCE
NOTE: Before plugging your Pit Boss into any electrical outlet, ensure the
temperature dial is in the OFF position.
•
STANDARD OUTLET
This appliance requires 120 volt, 60hz, 250W, 5 amp service. It must be a 3-prong
grounded plug. Ensure grounded end is not broken off before use. The control
uses a 5 amp, 120 volt, fast-blow fuse to protect the board from the igniter.
•
GFCI OUTLETS
This appliance will work on most GFCI outlets, with a recommended size of
15 amp service. If your GFCI outlet is highly sensitive to power surges, it will
likely trip during the start-up phase of operation. During the start-up phase,
the igniter draws 200-700 watts of electricity which can be too much power
for a GFCI outlet to handle. Each time it trips, it increases in sensitivity. If the
GFCI keeps tripping, replace the outlet or change to a non-GFCI outlet.