38
[50MXE20]
3.5.2 Hanging on the wall
Carefully read the following imformation before attempting to hang the unit on a wall. Take note of the various limitations
specified in this section. Mount the unit so that twisting, bending, or any other warping does not exceed 4 mm.
Shaded areas
indicate attachment points for mounting hardware.
Special Instruction (Hanging on the wall)
Operating temperature restrictions
✩
Standard single-unit installation
Distance from wall (A)
B
C
D
Ambient temperature
50 mm or less
300 mm or more
300 mm or more
300 mm or more
0 °C to 35 °C
50 mm or more
100 mm or more
50 mm or more
50 mm or more
0 °C to 40 °C
✩
Horizontal/vertical, left/right reverse installation (Note that only Examples 2 and 3 apply in cases
where the top and bottom are reversed)
* Regardless of the distance between the Plasma Display and the wall, the unit must be installed to allow
free air flow (no obstructions within a distance of 300 mm from the unit) around the panel.
Distance from wall (A)
B
C
D
Ambient temperature
50 mm or more
300 mm or more
300 mm or more
300 mm or more
0 °C to 35°C
✩
Requirements when used with PDP-S53-LR/PDP-S54-LR speaker system
When installed as a single unit, all requirements are the same as those listed above for horizontal/
vertical, left/right reverse installations. However, the figures listed above indicate the distance
between the speakers and the wall.
25
736
90
A
B
C
D
D
1222
50
Note
Different temperature restrictions apply to the PDK-5011 and PDK-WM01. Refer to “4.6 Tilt Mount Unit PDK-5011”
(pg. 104) and “4.7 Wall Mount Unit PDK-WM01” (pg. 110). For a wall-mount installation, allow adequate space (a
clearance of 300 mm or more) above, below, and to each side of the panel.
: Thermometer (temperature measurement point)