116
Ceiling Mount Unit: PDK-5012
4.8 Ceiling Mount Unit: PDK-5012
4.8.1 Specifications
External dimensions
................. 1222 mm (W)
×
1168 mm (H)
×
300 mm (D)
(48-1/8 in. (W)
×
45-31/32 in. (H)
×
11-13/16 in. (D))
(mounting hardware and Plasma Display <PDP-50MXE20>)
1022 mm (W)
×
1062 mm (H)
×
300 mm (D)
(40-1/4 in. (W)
×
41-13/16 in. (H)
×
11-13/16 in. (D))
(mounting hardware and Plasma Display <PDP-42MXE20>)
Weight
....................................... 14.5 kg (32.0 lbs.) (mounting hardware only)
50.0 kg (110.2 lbs.) (mounting hardware and Plasma Display <PDP-50MXE20>)
45.0 kg (99.2 lbs.) (mounting hardware and Plasma Display <PDP-42MXE20>)
Adjustable range of angles
...... Horizontal to 25 degrees below horizontal, 45 degrees left/right
Material
...................................... Steel pipe for general structure (STKM-R), STK, SPHC
Finish
.......................................... Semi-matte black paint (Original Pioneer color)
Package dimensions
................. 1035 mm (W)
×
360 mm (H)
×
540 mm (D)
(40-3/4 in. (W)
×
14-3/16 in. (H)
×
21-1/4 in. (D))
Package weight
......................... 21.5 kg (47.4 lbs.)
Layers of packing
...................... 10 layers
Components
PDP bracket ........................................................
×
1
Bolts M8 ..............................................................
×
6
Special screws ....................................................
×
4
Hole cover ...........................................................
×
1
Stencil (printed on the wrapping
material that is inside) .........................................
×
1
Installer's contact information (Japan only) .........
×
1
Operating instructions .........................................
×
1
The appropriate types of screws and other mounting hardware will depend on the strength and composition of the
ceiling. Purchase them separately.
✩
Operating Temperature Restrictions
• Ambient Temperature:
0 °C to 40 °C
✩
Operating Temperature Restrictions for Upside-Down Installations
(*1, *2)
• Ambient temperature:
0 °C to 40 °C
• Other factors:
Maintain sufficient clearance between the display and the wall (at least 300 mm)
✩
Operating temperature restrictions for when the speaker system (PDP-S53-LR, PDP-S54-LR, PDP-S56-LR)
is attached.
• Ambient temperature:
0 °C to 40 °C
*1
For this installation, set the ‘FAN CONTROL’ to ‘MAX’ as shown in “5.4.3 Adjustment and Setting in the Integrator Mode 14)
Cooling Fan Control Setting” (pg. 211).
*2
When INPUT2 has been selected, use input compatible signal up to 1280x1024 (60 Hz) at ambient temperature condition of 0 °C
to 35 °C.
[50MXE20 : 42MXE20]