66
DJM-850-K
1
2
3
4
A
B
C
D
E
F
1
2
3
4
9
Mode 10 : AD values of the rotary VRs test. "VOL AD"
An amplitude value in the range of ±1 to ±6 with regard to the
V
R value at the beginning of measurement is displayed.
For a value greater than +7 or less than -7, all the 7 segments are lit.
• Mode for displaying the AD values of rotary
V
Rs on the FL display for confirmation.
W
hen this mode is entered, “
V
OL AD” is displayed at the top of the FL display.
To indicate the AD values for several rotary
V
Rs with a single level meter, the rotary
V
Rs are divided into 4 groups.
The group pages can be changed by pressing the BEAT
c
,
d
button.
W
hen the groups are switched, the name of the
V
R at the top of the group list is displayed at the bottom of the FL display.
The rotary
V
Rs in a group can be changed by pressing the CH1–4 CUE button.
• The maximum amplitude value among AD conversion values for a rotary
V
R being tested can be confirmed on each page
of this mode.
The value is expressed with the number of segments lit at the bottom of the FL display. The measurement procedure is as
indicated below.
Turn the rotary
V
R you wish to test to a desired position then press the EFFECT CUE key to start measurement. To reset,
press the EFFECT CUE key again. During measurement, the maximum amplitude value will be continuously displayed.
The EFFECT CUE key is lit during measurement and goes dark when reset.
Details on the amplitude value display are shown in the figures below.
Group 4
Group 3
Group 2
Group 1
Note:
If the CUE button is pressed while the last
V
R on each group list is displayed, the top
V
R on that group list will then
be displayed.
W
hen the BEAT
c
,
d
button is pressed for a layer lower than the 2nd one, the top
V
R on the list of the next group
will be displayed.
N
ame of the
rotary
V
R
AD value
(in hexadecimal
notation)
Amplitude
value
CH1
CUE button
CH2
CUE button
CH3
CUE button
CH4
CUE button
BEAT
d
button
BEAT
c
button
BEAT
d
button
BEAT
c
button
BEAT
d
button
BEAT
c
button