Function description
Operating Manual PSEN sc L 3/5 series
1005056-EN-01
| 18
OSSD
EDM
2
t
1
t
On
Off
24 V
0 V
Fig.: Timing diagram for EDM
Legend
t
1
After the OSSD outputs are switched on, the EDM circuit must open within 350 ms
t
2
After the OSSD outputs are switched off, the EDM circuit must close within 100 ms
Use control elements whose dynamics match the times stated at t
1
and t
2
.
The function is activated or deactivated with the
4.8
Wave
With the wave function, a safety laser scanner that is to be configured in a network can be
identified more easily from its position.
When starting the automatic search for a safety laser scanner in a network the wave button
can be selected.
The device found registers with the flashing message
in the display.
4.9
Muting
The muting function can be used to suspend the safety laser scanner during operation,
subject to special operating conditions.
}
Example of a special operating condition:
Material is transported into the protective zone on a conveyor and the safety laser scan-
ner is overridden for the time it takes the material to pass through.
Muting proves to be particularly suitable when, under certain operating conditions, an object
is permitted to pass through the danger zone but a person is not.