PSENscan Configurator
Operating Manual PSEN sc L 3/5 series
1005056-EN-01
| 62
INFORMATION
To ensure that PSENscan Configurator functions correctly, the files and dir-
ectories in the installation directory of PSENscan Configurator must not be
modified manually once installed (e.g. with the Windows Explorer or a text
editor).
8.2.3
Ethernet Connections
8.2.3.1
Factory default settings for the IP addresses
The factory-set default of the IP address of the safety laser scanner: 192.168.0.10.
INFORMATION
Use the correct IP address
A second address has been set up for internal functions of the safety laser
scanner. This address always follows directly after the IP address, specified
in the network settings.
– Ensure that only on IP address is used when the following IP address
is not assigned.
8.2.3.2
Create firewall rule
A firewall or any other security mechanisms on the PC and network may prevent the
PSENscan Configurator from communicating correctly with the connected devices. In this
case, it will be necessary to adjust the security settings and firewall settings.
Firewalls allow access to explicitly registered programs. The following program must have
access to the profile
Private
:
}
PSENscan Configurator
8.2.3.3
Connect automatically
The PSENscan Configurator offers the option of automatically finding a device available in
the network.
1. Select
Device -> Search device
.
The network is searched for connected devices of the PSEN sc L 3/5 series.
Connected devices of the PSEN sc L 3/5 series are listed under
Network environ-
ment
.
To locate the PSEN sc L 3/5 series click the button
. The wave symbol is
shown on the display of the selected PSEN sc L 3/5 series.