Project configuration
Operating Manual PSEN sc L 3/5 series
1005056-EN-01
| 36
Allowance Z
R
with distances below the recommended minimum distances to intense
light sources or reflective surfaces
If the recommended distances cannot be met, the allowance Z
R
must be considered when
calculating the safety distance [
.
The value for the allowance Z
R
depends on the selected level of the dust filter, on the selec-
ted detection capability and on the determined safety distance without this allowance.
Safety distance
(K*T)+C+Z
without Z in m
R
T
Allowance Z
in mm
R
[1]
[2]
[3]
1
2
3
4
5 5,5
50
100
150
200
250
300
350
400
Fig.: Allowance with a detection capability of 70 mm
Legend
[1] Low level
[2] Medium level
[3] High level