First commissioning
Operating Manual PSEN sc L 3/5 series
1005056-EN-01
| 68
WARNING!
Loss of safety function due to a safety distance that is too low
Depending on the application, serious injury or death may result.
}
Depending on the degree of dust filtering, it is necessary to consider an
allowance for calculating the safety distance when installing the safety
laser scanner near intense light sources or reflective surfaces into ac-
count (see
Distance to intense light sources and to reflective
– When calculating the safety distance, ensure that the allowance is
considered depending on the dust filtering.
– Ensure that the new safety distance fulfils the specifications of the
safety assessment.
11. Click on the arrow
. The next window
Configure zones
is opened.
Create the zones using the symbols in the tool bar on the right-hand side.
12. Click on
.
Specify at least 3 (max. 15) reference points. Specify a max. permitted tolerance for
each reference point.
Tol -
is the tolerance for the side that faces the safety laser scan-
ner,
Tol +
is the tolerance for the side that is facing away from the safety laser scanner.
9.3.2
Example for an 12-pin connection
Settings in PSENscan Configurator for a safety laser scanner with 12‑pin connection: Ver-
tical application with reference contour monitoring, 1 zone set, 1 warning, manual restart
Procedure:
1. From the start page, select
Create new configuration
.
The window
Device selection
is displayed with one tab each
Online
and
Overview of
all types.
2. Select a device from
Overview of all types
. Double-click the device.
The device is displayed in the work window and it can be configured
.
3. Under
Application
, select VERTICAL and
12-pin connection
.
Configuration
You can enter a title for the configuration under
Name
.
You can enter the name of the person who created the configuration under
Author
.
You can describe the configuration in detail under
Description
.
The
Configurator Version
is entered by the system and cannot be changed.
The
Check sum
is entered by the system and cannot be changed.
The
Creation date
is entered by the system and cannot be changed.