OPERATING MANUAL
PSEN op2H-A series
11 LIST OF AVAILABLE MODELS
Protected
field
height
No. of
beams
Response
time
Resolution
Test rate
Rt
1)
Demand rate
Rd
1)
Model
mm
ms
mm
1/s
1/min
PSEN op2H-A-30-030/1
300
16
13
30
77
46
PSEN op2H-A-30-045/1
450
24
14
30
71
43
PSEN op2H-A-30-060/1
600
32
15
30
67
40
PSEN op2H-A-30-075/1
750
40
16
30
63
38
PSEN op2H-A-30-090/1
900
48
17
30
59
35
PSEN op2H-A-30-105/1
1050
56
18
30
56
33
PSEN op2H-A-30-120/1
1200
64
19
30
53
32
PSEN op2H-A-30-135/1
1350
72
19
30
53
32
PSEN op2H-A-30-150/1
1500
80
20
30
50
30
PSEN op2H-A-30-165/1
1650
88
21
30
48
29
PSEN op2H-A-30-180/1
1800
96
22
30
45
27
1)
:
The following applies for EN ISO 13849-1:2008 Category 2: Demand mode must
be
≤
1/100 of the test rate.
1003069-EN-03
55