OPERATING MANUAL
PSEN op2H-A series
6 SETTING THE FUNCTIONS
In basic configuration mode you have the option to use the buttons and the LED interface
(transmitter/receiver) to select basic functions/parameters.
Basic configuration mode
The user interface consists of 8 LEDs and 3 protected pushbuttons and enables the user to
perform the basic configuration. The LEDs are the same LEDs used to display status in
normal operating mode.
A plastic pen is provided (see Chapter 13), which the user must use to activate the
pushbuttons, thus preventing unwanted access to the safety configuration.
Basic configuration steps
On the right-hand side of the operator panel at transmitter and receiver there is a settings
interface, consisting of three pushbuttons. The interfaces give users the option to set the light
curtain locally, without using the PSENopt Configurator.
•
CONFIRM button activates the BCM configuration mode
•
SELECT button: The different functions are run through.
•
ENABLE button: Activates and deactivates the currently selected function.
The individual steps are described below:
1. Press the
CONFIRM
button and keep it held down to switch to basic configuration
mode.
2. The light curtain runs through a test cycle. With the transmitter the LEDs 2 and 3 light
up one after the other, with the receiver the LEDs 2 to 8. The Power LED 1 is
constantly lit.
After the test cycle is completed, the current configuration is displayed
3. Use the
SELECT
function to choose the function that is to be set. The LED for the
selected function will flash.
4. Now configure the selected function by pressing the
ENABLE
button (LED lights/goes
out).
5. Repeat steps 3 and 4 until the required configuration is displayed.
6. Press the
CONFIRM
button and keep it held down to save the new configuration.
32
1003069-EN-03