OPERATING MANUAL
PSEN op2H-A series
10 TECHNICAL DETAILS
Electrical data
Operating voltage:
24 V DC ±20%
Current consumption transmitter (TX):
Max. 3 W
Current consumption receiver (RX):
5 W max (without load)
Outputs:
2 PNP
- Short circuit protection:
1.4 A max
- Output current:
0.5 A max. at each output
- Output voltage – Status ON:
Operating voltage – 1 V min
- Output voltage – Status OFF:
0.2 V max.
- Capacitive load:
2.2 uF at 24 V DC max
Response times:
See table below
Reset time:
100 ms
Reset time when Sync interrupted:
2 Sec.
Height of protected field:
300..1800 mm
Category:
Type 2 (ref. to EN 61496-1)
SIL 1 (ref. to EN 61508)
SIL 1 (ref. to EN 62061)
PL c and Cat. 2 (ref. to EN ISO 13849-1:2008)
PFHd [1/h] = 1.04E-08
MTTFd [years] = 273
Auxiliary functions:
Test; manual/automatic restart; EDM; reset;
muting
Protection class:
Class III (see Ch. 4.1)
Current for external lamp:
20 mA min.; 300 mA max.
Connections:
- M12 12-pin + M12 5-pin for receiver (muting
model)
- M12 5-pin for transmitter (for both models)
Cable length (for supply):
50 m max.
Optical data
Transmitter light (
λ
):
Infra-red, LED (950 nm)
Resolution:
30 mm
Operating range:
0.2…20 m for 30 mm
Ambient brightness:
IEC-61496-2
Environmental data and mechanical data
Operating temperature:
0…+ 50 °C
Storage temperature:
- 25…+ 70 °C
Temperature class:
T6
Humidity:
15…95 % (non-condensing)
Protection type:
IP 65 (EN 60529)
Vibration:
- Amplitude 0.35 mm,
- Frequency 10 … 55 Hz
- 20 sweeps per axis,
- 1 octave/min. (EN 60068-2-6)
Max. acceleration:
10 g
(EN 60068-2-29)
Housing material:
Varnished aluminium (yellow RAL 1003)
Front surface material:
PMMA
Terminator cap material:
PBT Valox 508 (RAL 7021)
Cover material:
PC LEXAN
Weight:
1.35 kg per running metre per individual unit
54