OPERATING MANUAL
PSEN op2H-A series
7.7.5 Muting timeout
The muting timeout describes the time for the maximum duration of the muting function; once
the timeout has elapsed, muting is ended.
The user has the option to set this time.
He can select a timeout to be 10 minutes or infinite; "infinite" means that the muting timeout
may potentially never end: as long as the muting conditions are present, the muting function
will be maintained.
NOTE: This does not comply with the standard IEC 61496-1 and the user is
informed of this fact via a message
Fig. 45 – Muting timeout
BCM configuration: Muting timeout
P
W
R
O
S
S
D
E
DM
A
CM
LEVEL
10 min
LED 7 ON green
Infinite
LED 7 OFF
NOTE: The infinite timeout option does not comply with the standard
IEC 61496-1 and the user is warned accordingly.
.
46
1003069-EN-03