PSEN ma1.4-51 M12/8-0.15m
Operating Manual PSEN ma1.4-51 M12/8-0.15m
22185-EN-05
8
Operating distances
S
ao
S
o
S
r
S
ar
(mm)
S
omin
On
Off
Legend
S
ao
Assured operating distance
S
omin
Min. operating distance
S
ar
Assured release distance
The offset-independent values for the switching distances are included in the
Technical
details [
17]
.
Lateral and vertical offset
[1]
[2]
Legend
[1] Lateral offset
[2] Vertical offset
Actuator PSEN ma1.4-03
Assured operating distance S
ao
in mm
Vertical offset
Lateral offset
0
1
2
3
4
0
3.0
3.0
2.5
1.5
1.0
1
3.0
2.5
2.0
0.5
-
2
2.5
1.5
1.0
-
-
3
1.5
0.5
-
-
-
4
0.5
-
-
-
-