Use of qualified personnel

The products may only be assembled, installed, programmed, commissioned, operated,
maintained and decommissioned by competent persons.
A competent person is a qualified and knowledgeable person who, because of their train-
ing, experience and current professional activity, has the specialist knowledge required. To
be able to inspect, assess and operate devices, systems and machines, the person has to
be informed of the state of the art and the applicable national, European and international
laws, directives and standards.
It is the company’s responsibility only to employ personnel who

}

Are familiar with the basic regulations concerning health and safety / accident preven-
tion,

}

Have read and understood the information provided in this description under "Safety"

}

Have a good knowledge of the generic and specialist standards applicable to the spe-
cific application.

Warranty and liability

All claims to warranty and liability will be rendered invalid if

}

The product was used contrary to the purpose for which it is intended

}

Damage can be attributed to not having followed the guidelines in the manual

}

Operating personnel are not suitably qualified

}

Any type of modification has been made (e.g. exchanging components on the PCB
boards, soldering work etc.).

Disposal

}

In safety-related applications, please comply with the mission time T

M

 in the safety-re-

lated characteristic data.

}

When decommissioning, please comply with local regulations regarding the disposal of
electronic devices (e.g. Electrical and Electronic Equipment Act).

For your safety

WARNING!

Loss of safety function due to manipulation of the interlocking device
Manipulation of the interlocking device may lead to serious injury and death.

– You should prevent any possibility of the interlocking device being

manipulated through the use of a spare actuator.

– Keep the substitute actuator in a safe place and protect it from unau-

thorised access.

– If spare actuators are used, these must be installed as described in

Installation [

 13]

.

– If the original actuators are replaced with substitute actuators, the ori-

ginal actuators must be destroyed before disposal.

Summary of Contents for PSEN ma1.4-51 M12/8-0.15m

Page 1: ...PSEN ma1 4 51 M12 8 0 15m Operating Manual 22185 EN 05 PSEN sensor technology...

Page 2: ...umentation will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Interne...

Page 3: ...liability 6 Disposal 6 For your safety 6 Unit features 7 Function description 7 Block diagram 7 Operating distances 8 Lateral and vertical offset 8 Wiring 9 Pin assignment 9 Requirements and connectio...

Page 4: ...rmation that is particularly important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indi...

Page 5: ...product outside the technical details see Technical details 17 NOTICE EMC compliant electrical installation The product is designed for use in an industrial environment The product may cause interfere...

Page 6: ...warranty and liability will be rendered invalid if The product was used contrary to the purpose for which it is intended Damage can be attributed to not having followed the guidelines in the manual Op...

Page 7: ...ils 17 Design Safety switch with square design Actuator with square design PSEN ma1 4 03 Actuator with square design PSEN ma1 4 10 Operation Magnetic Switching voltage 24 VDC LED to display switch sta...

Page 8: ...elease distance The offset independent values for the switching distances are included in the Technical details 17 Lateral and vertical offset 1 2 Legend 1 Lateral offset 2 Vertical offset Actuator PS...

Page 9: ...tance sensor see Technical details 17 Rl km Cable resistance km of the cable see technical details cable Ensure the wiring and EMC requirements of EN 60204 1 are met In the following cases check the f...

Page 10: ...For use of PSEN ma1 4 51 M12 8 0 15m in accordance with DIN EN 60947 5 3 an evalu ation device must be connected Connect the PSEN ma1 4 51 M12 8 0 15m either with a certified Pilz evaluation device or...

Page 11: ...onitoring of the safety switch is performed The inputs and outputs of the evaluation device must fulfil the requirements of IEC 61131 Technical data of the evaluation device must fulfil the requiremen...

Page 12: ...21 S12 S22 2 3 4 5 6 7 8 white green yellow pink PNOZ s3 PSENmag yellow white pink green T0 I0 T1 I1 1 2 3 4 5 6 7 8 PNOZmulti PSENmag Auxiliary contact with LED The auxiliary contact and the LED indi...

Page 13: ...screws with a flat head e g M4 cheese head or pan head screws Use screws made of non magnetic mater ial e g brass CAUTION Potential loss of safety function due to changed device properties The unit s...

Page 14: ...fields Should be used for fixed wiring only Prevent the safety switch and actuator being exposed to heavy shock or vibration Make sure that the safety switch and actuator cannot be used as an end stop...

Page 15: ...Diagram 15 9 Close unused mounting holes using seal 2 see Diagram 15 10 Close mounting holes on the sensing face using seal 3 see Diagram 15 11 Installation of sensor and actuator is now complete 1 2...

Page 16: ...actuator and tighten screws with max 0 8 Nm 5 Close used mounting holes using seal 1 or 4 see Diagram 16 6 Close mounting holes on the sensing face using seal 3 see Diagram 16 7 Installation of senso...

Page 17: ...see Operating distances and Lateral and vertical offset 8 Periodic test Carry out a monthly function test on the safety switch and actuator Always test the function with a connected evaluation device...

Page 18: ...x switching current auxiliary contacts 10 mA 10 mA Times 506344 506345 Reaction time actuator removed 2 ms 2 ms Environmental data 506344 506345 Ambient temperature Temperature range 10 55 C 10 55 C C...

Page 19: ...ollow installation guidelines Connection type M12 8 pin male connector M12 8 pin male connector Cable LiY11Y 8 x 0 14 mm2 LiY11Y 8 x 0 14 mm2 Material Top PBT PBT Max torque setting Safety switch 0 8...

Page 20: ...ith assured operat ing distance 3 mm 506 300 PSEN ma1 4 10mm 1actuator Actuator with assured operat ing distance 10 mm 506 301 Accessories Cable Product type Connection 1 Connection 2 Length Order no...

Page 21: ...fetyNET p THE SPIRIT OF SAFETY are registered and protected trademarks of Pilz GmbH Co KG in some countries We would point out that product features may vary from the details stated in this document d...

Reviews: