PSEN ma1.4-51 M12/8-0.15m
Operating Manual PSEN ma1.4-51 M12/8-0.15m
22185-EN-05
10
Assignment of
the 8-pin con-
nector
pink
green
white
yellow
brown
blue
3
5
2+
4
6
1
7
8
grey
red
NC
NC
NOTICE
The auxiliary contact with LED
– May only be operated with a supply voltage of up to 24 VDC with
PNOZ X units
– May not be connected in series with PNOZ X, PNOZelog and
PNOZmulti units
– may
not
be used for safety circuits
Requirements and connection to evaluation devices
For use of PSEN ma1.4-51 M12/8-0.15m in accordance with DIN EN 60947-5-3 an evalu-
ation device must be connected.
Connect the PSEN ma1.4-51 M12/8-0.15m
}
either
with a certified Pilz evaluation device
}
or
with an evaluation device with defined properties
Certified Pilz evaluation devices are, for example:
}
PNOZelog for safety gate monitoring
– PNOZ e1p, PNOZ e1.1p, PNOZ e1vp
– PNOZ e5.11p
– PNOZ e6vp, PNOZ e6.1p
}
PNOZpower for safety gate monitoring
– PNOZ p1p, PNOZ p1vp
}
PNOZsigma for safety gate monitoring:
– PNOZ s3
– PNOZ s4
– PNOZ s5
}
PNOZ X for safety gate monitoring
– PNOZ X2, PNOZ X2.5P, PNOZ X2.7P, PNOZ X2.8P, PNOZ X2.9P, PNOZ X2C,
– PNOZ X3, PNOZ X3.1, PNOZ X3P, PNOZ X3.10P
– PNOZ X4