Wiring
Operating Manual PMCprotego S12(C)
1002528EN03
61
Input circuit
Digital input
1
I0
2
3
4
0V
12
24 V
I/O-GND
X30
I4
I3
I2
I1
I5
13
14
21, 22
SS1 Activate
15
I6
20
SS1 SIL3/Reset
Shield
Servo Amplifier
Shield
Shielded cable
Max. cable length: 30 m
24 VDC
Referenced to earth:
X30, Pin 21, 22 are linked
internally
Connection
6.5
Digital outputs
6.5.1
Supply voltage
The digital outputs need a 24 VDC supply.
}
When selecting the power supply, please refer to the requirements stated under “Tech
nical Details”.
}
The power supply must be able to bridge a power outage of 20 ms.
WARNING!
Electric shock!
Safe electrical isolation must be ensured for the external power supply that
generates the supply voltage. Failure to do so could result in electric shock.
The power supplies must comply with EN 609501, 05/2006, EN 6155826,
11/1997.