8.11
Writing a parameter
Parameter v_max is used as an example to show how control parameters are transmitted from the
master to the PMCtendo DD4.
Parameter number:
1265
100 1111 0001
Parameter value:
350000
µm/s
0000 0000 0000 0101 0101 0111 0011 0000
Byte 1
2
3
4
5
6
7
8
0011|0100 1111 0001 0000 0000 0000 0000 0000 0000 0000 0101 01010111 0011 0000
AK |
PKE
IND
PWE
Note: after an error has occurred in parameter transmission (AK = 7), a “Zero telegram” should be
transmitted, i.e. the first 8 bytes of the transmit telegram from the PLC should be kept at 0, until the
PMCtendo DD4 has responded with a zero telegram.
8.12
Read actual values
Cyclical actual value request
This PKW task switches on the reading of an actual value. The actual value will now be transmitted
with each cyclical telegram – until a new PKW task is presented.
Telegram layout:
Request
Response
PKE/AK
1
2
PKE/PNU Parameter number of the actual values (1400..1413)
as transmitted
IND
0 =
read
0
PWE
no significance
actual value
User manual PROFIBUS DP PMCtendo DD4
Page 53
8 Sample telegrams