5.2.10
Manufacturer specific object channel (from PNU 1600)
The object catalogue was expanded by all existing parameters and commands from PNU 1600 on
(reserved object range PNU 1600 - PNU 2000).
This object range is called SDO channel (SDO - Service Data Object). The SDO channel is
expansible dynamically, new parameters will be added to the table
automatically
. The PNU is cal-
culated by 1600 + ASCII object number.
Each of the object in the SDO channel is described by 8 subindexes (octet 3).
In the following, the structure of the subindexes is shown:
Subindex
0
short description
Number of entries
Unit
—
Access
—
Data-type
UNSIGNED8
Value range
0 ... 2
8
-1
EEPROM
—
Subindex
1
short description
read/write a parameter
Unit
see corresponding ASCII-command
Access
see corresponding ASCII-command
Data-type
see corresponding ASCII-command
Value range
see corresponding ASCII-command
Defaultvalue
—
EEPROM
see corresponding ASCII-command
Subindex
2
short description
read lower limit
Unit
see corresponding ASCII-command
Access
Read only
Data-type
see corresponding ASCII-command
Value range
see corresponding ASCII-command
Defaultvalue
—
EEPROM
—
Subindex
3
short description
read upper limit
Unit
see corresponding ASCII-command
Access
Read only
Data-type
see corresponding ASCII-command
Value range
see corresponding ASCII-command
Defaultvalue
—
EEPROM
—
Subindex
4
short description
read defaultvalue
Unit
see corresponding ASCII-command
Access
Read only
Data-type
see corresponding ASCII-command
Value range
see corresponding ASCII-command
Defaultvalue
—
EEPROM
—
User manual PROFIBUS DP PMCtendo DD4
Page 33