Using the parameter channel
The digital servo amplifiers of the PMCtendo DD4 series have to be adapted to the circumstances
of your machine. The parameters for the controllers are set using either the setup Software PDrive
or via the PROFIBUS.
5.1
Read/write an amplifier parameter
Read (AK = 1) or write (AK = 3) amplifier parameters
To read or write an amplifier parameter, which is recognized by the parameter number (PNU), to the
volatile
memory of the PMCtendo DD4. The parameters that are stored in the PMCtendo DD4 can
be transferred to the
non-volatile
memory by using the command “non-volatile parameter save”
(PNU 971).
Telegram layout:
Request
Response
PKE/AK
1 (read) / 3 (write)
2 (OK) / 7 (error)
PKE/PNU
see 5.2.1
as transmitted
PWE
for AK = 3 see 5.2.1 for data type
for AK = 1 data type irrelevant
for AK = 3 returns the PWE of the request
for AK = 1 see 5.2.1 for data type
5.2
Summary of the parameter numbers
All the parameter numbers for PMCtendo DD4 are listed in numerical order in the table in Chapter
5.2.1, with a short description. The parameter numbers in the range 900 – 999 are profile-specific
for the PROFIBUS drive profile PROFIDRIVE. Parameter numbers > 999 are manufacturer- spe-
cific.
For better understanding, you can look up the ASCII commands which are in the column
“PMCtendo DD4 ASCII command” in the user manual for the Setup Software PDrive.
This section deals only with parameters that refer to the PROFIBUS expansion card and have not
already been described in the setup software manual. The attachment runs via the ASCII-com-
mands.
5.2.1
List of the parameter numbers
PNU
Data type
Access Description
PMCtendo DD4
ASCII command
Profile parameter
904
UINT32
ro
Number of the supported PPO-write, always 2
-
911
UINT32
ro
Number of the supported PPO-read, always 2
-
918
UINT32
ro
Participant address on PROFIBUS
ADD
930
UINT32
r/w
Selector for operating mode
-
963
UINT32
ro
PROFIBUS baud rate
-
965
Octet-String2
ro
Number of the PROFIDRIVE profile (0302H)
-
970
UINT32
wo
Load default parameter set
RSTVAR
971
UINT32
wo
non-volatile parameter save
SAVE
1204
UINT32
r/w
Setpoint ramp-, speed controller
DEC
1205
UINT32
r/w
Emergency stop ramp, speed controller
DECSTOP
1206
UINT32
r/w
Maximum speed
VLIM
1207
UINT32
r/w
Overspeed
VOSPD
1208
UINT32
r/w
Count direction
DIR