55
SSM-ICON
Use, maintenance and warning manual
Static SmaRt mEtER
|
iNStaLLatiON
|
REV. B
EN
7.4 - SPECIFIC SAFETY INSTRUCTIONS FOR THE INSTALLATION STEP
NOTICE!
The equipment is supplied with its battery packs already inserted and connected, therefore, once installed,
it is ready for use.
WARNING!
Before proceeding with installation, make sure that the upstream and downstream valves installed on the
line are closed.
WARNING!
Installation may also take place in areas where there is a risk of explosion, and this implies that all neces-
sary prevention and protection measures must be taken.
For these measures, please refer to the regulations in force at the place of installation.
WARNING!
Near the equipment, do not:
•
use open flames (e.g. for welding operations);
• smoke.
WARNING!
Before connecting, make sure that:
• at least the portion of the system upstream of the equipment has been cut off and that, therefore, no
flow of gas occurs during installation;
• the maximum system pressure is lower than the maximum pressure set for the equipment, which is
fixed and equal to 0.5 relative bar.
WARNING!
Install the equipment with the indicator device in a horizontal position, not in direct contact with the wall
and raised from the floor.
WARNING!
During the equipment installation:
•
avoid mechanical stresses on its inlet/outlet connections;
• implement protective measures against electrostatic discharges.