43
SSM-ICON
Use, maintenance and warning manual
Static SmaRt mEtER
|
USER iNtERFacE
|
REV. B
EN
5.3.6 - CHAPTER 4 (COMMUNICATION)
tab. 5.33., tab. 5.34. and tab. 5.35. indicate the sequences for viewing the pages of the chapter, by model:
Models with GPRS type of remote communication
Sequence
Explanatory field
Description
1
tc
communication test Page.
2
Qc
current cSQ value (99 = not detected).
3
ic
icciD code (if detected).
Tab. 5.33.
Models with RF 169 MHz type of remote communication
Sequence
Explanatory field
Description
1
tc
communication test Page.
Tab. 5.34.
Models with NB-IoT type of remote communication
Sequence
Explanatory field
Description
1
St
Strategy currently active according to standard UNi/tS 11291-12-2):
•
0
= Normal operation (valve open);
•
1
= User disconnected (valve closed);
•
2
= Orphaned Gdm.
2
tc
communication test Page.
3
Ec
Value EcL 0-2 (99 = not detected).
4
RQ
Value RSRQ: 0 (-19,5 dBm) at 32 (-3dBm) (99 = not detected).
5
RP
RSRP value: 0 (-140 dBm) at 95 (-44dBm) (99 = not detected).
6
ic
icciD code (if detected).
Tab. 5.35.
5.4 - ALARMS
the lighting of the alarm icon on the display indicates that one or more of the following error conditions are in progress:
• error in the measuring system;
• unauthorised battery door opening error (tampering);
• integrity error of the firmware code;
• temperature out of range or in error;
• reverse flow beyond threshold error (default >150 dm
3
, programmable).