34
SSM-ICON
EN
Use, maintenance and warning manual
Static SmaRt mEtER
|
DEScRiPtiON aND OPERatiON
|
REV. B
4.3 - TECHNICAL DATA
General features
Electronic casing
Polycarbonate
Casing protection rating
iP55 (iP66 on request)
Maximum working pressure
0.5 bar
Operative temperature range
from -25 °c to +55 °c
Gas temperature range
from -25 °c to +55 °c
Temperature sensor
integrated
Real time clock
accuracy according to EN62054-21
Measurement precision
class 1.5
ATEX marking
ii 3G Ex ic iiB t3 Gc
Tubing connections
1’’ 1/4 iSO 228
Tab. 4.20.
Remote communication features
Communication band
• SSm-icON-U6-GPRS: Quad-band;
• SSm-icON-U6-NB: Band 20 (default), 3, 5, 8, 25, 28;
• SSm-icON-U6-169: Wireless m-Bus 169mHz (mode N2).
Tab. 4.21.
Battery features
Metrological battery pack
type: Non-rechargeable battery Li-SOcl
2
3,6V, Size c - D
autonomy: Size c >15 years
Size D > 20 years (“Extended Life” version models)
Communication battery pack
SSM-ICON-U6-GPRS*
Identifier type: D09**
type: Non-rechargeable battery Li-SOcl
2
3,6V, Size D
autonomy: > 8 years
Communication battery pack
SSM-ICON-U6-NB*
Identifier type: D09**
type: Non-rechargeable battery Li-SOcl
2
3,6V, Size D
autonomy: > 20 years
Communication battery pack
SSM-ICON-U6-169*
Identifier type: C01**
type: Non-rechargeable battery Li-SOcl
2
3,6V, Size c
autonomy: > 20 years
* Replaceable in the field
** The “identifier type” of the battery pack must be specified
when ordering new parts to be replaced in the field.
Tab. 4.22.