Rev. 01/2020
34
Capacitor Voltage
These commands give access to the capacitor bank pre charger.
Current control
These commands give access to the current regulator.
Analogue digital converter
These commands give access to the analogue to digital converter and its internal and pulse
measurements.
Command Name
Command frame
Answer frame
Command
Data
Command Data
GETVCAP
0x0500
0
0x8500
Uint32 in 0.1 V
GETVCAPMIN
0x0501
0
0x8500
Uint32 in 0.1 V
GETVCAPMAX
0x0502
0
0x8500
Uint32 in 0.1 V
SETVCAP
0x0503
Uint32 in 0.1 V
0x8500
Uint32 in 0.1 V
Command Name
Command frame
Answer frame
Command
Data
Command
Data
GETCUR
0x0600
0
0x8600
Uint32 in A
GETCURMIN
0x0601
0
0x8600
Uint32 in A
GETCURMAX
0x0602
0
0x8600
Uint32 in A
SETCUR
0x0603
Uint32 in A
0x8600
Uint32 in A
Command Name
Command frame
Answer frame
Command
Data
Command
Data
GETADCUDIODE
0x00C0
0
0x01C0
Uint32 in V
GETADCIDIODE
0x00C1
0
0x01C0
Uint32 in A
GETADCVCAP
0x00C2
0
0x01C0
Uint32 in 0.1 V
GETADCUIN
0x00C5
0
0x01C0
Uint32 in 0.1 V