Command
Parameter
Description
gcount
-
returns the actual configured number of pulses to be
generated
gcountmin
-
returns the minimum possible number of pulses to be
generated
gcountmax
-
returns the maximum possible number of pulses to be
generated
scount
number
sets the number of pulses to be generated
execpuls
-
generates a software trigger
strgmode
0 … 3
sets the pulse generator trigger mode to the given value
Mode 0: internal
Mode 1: external
Mode 3: external controlled
Mode 4: software controlled
See section “Trigger Modes” for more information
gtrgmode
-
returns the actual used trigger mode
strgedge
0 or 1
Sets the edge detection polarity to the given value.
0: positive
1: negative
Please note that it is used only in trigger modes 1 and 2.
See section “Trigger Modes” for more information.
gtrgedge
-
Returns the actual configured polarity
gtemp
-
returns the value of temp. sensor in [°C]
gtemphys
-
returns the temperature at which the device switches back
on after an overtemperature shutdown in [°C]
gtempwarn
-
returns the temperature at which the TEMP_WARN bit in
the ERROR register is set
gtempoff
-
returns the overtemperature shutdown value in [°C]
enable_ext
-
Sets the enable input control to external
enable_int
-
Sets the enable control input to internal
enable
-
Enables the driver. Only useable in internal control.
disable
-
Disable the driver. Only useable in internal control.
slstat
32-bit number
Sets the LSTAT register to the given value
glstat
-
Returns the contents of the LSTAT register in one 32-bit
number