-11-
5.6 Hose Connection between each part
1. Connect the raw water adaptor assembled in the cold water side and the inlet hole of
head connector assay. In this case, make sure that the hose is not bent or twisted.
2. Connect the hose between the outlet hole of head connector assay and one touch fitting
connected to a faucet.
Caution
: Refer to Fig. 1. Working Drawing of page 3.
5.7 System Operation and Leakage Check
Caution : Before operating the system, be sure to check if the pipe is connected
correctly and verify the installation once again. Check if the components
are connected with each other firmly.
1. Before operating the system, check the following.
The faucet should be unlocked. (Turn the faucet handle to CCW)
2. Open the raw water supply valve slowly.
After a while, check if the purified water is coming out from the faucet.
Check the leakage of each part.
3. If the purified water is coming out normally, close the faucet.
Check the leakage of each part.
4. If there is no leakage, open the faucet once again.
Let the purified water run for about 5 minutes and then lock the faucet.
5. If the water tastes abnormal or smells bad, repeat the above 4 steps.