- Unscrew the fastening screw and remove the gas
outlet union with the relevant O-ring.
- Check that the mounting surface of the crankcase
is not worn or deformed.
- Check that the by-pass valve seat and the torque
limiter bearing are free from wear.
Characteristic
By-pass housing hole diameter:
13.9 mm
Connection diameter for start-up gear shaft:
12 mm
Connection diameter for pump shaft:
8 mm
- Check that the oil filter union and matching sur-
face exhibit no deformations or wear.
- Check the condition of the stator and the relevant
cable harness.