YES go to 15 NO go to 14
14
- Repair or replace the wiring.
Check the air temperature lines and the throttle
valve position.
YES go to 15
15
- Connect the special tool to the control unit.
Set the switch to "
ON
" with switch to "
RUN
" and
side stand raised.
YES go to 16
Specific tooling
020481Y
Control unit interface wiring
16
- Measure voltage at terminals 4 and 22;
TEMPERATURE VOLTAGE
Specification
Desc./Quantity
1
X V
-10° C
2
X V
0
3
X V
+10° C
4
X V
+20° C
5
X V
+30° C
6
X V
+80° C
YES go to 21 NO go to 17
17
Repeat the wiring and sensor continuity checks.
YES go to 18
18
Electric characteristic
XEVO 400ie
Injection
INJEC - 237