YES go to 16 NO go to 19
16
- Check the earth insulation of the primary circuit
Measure between one of the primary terminals and earth.
Electric characteristic
Primary-earth =
Ω
infinite (>1M
Ω
)
YES go to 17 NO go to 1 9
17
- Check the secondary resistance.
Measure the resistance between one of the primary terminals and the spark plug cable output
Electric characteristic
Primary HV cable output =
3.1 ± 9% K
Ω
YES go to 18 NO go to 19
18
- The coil is conforming.
19
- Replace the coil
Injection
XEVO 400ie
INJEC - 230