5 Installation
12
Version: 1.2.0
MP164E
L-402 Mniature Stage
INFORMATION
The use of locating pins during mounting reduces deviations from the ideal alignment of the
stage.
If possible, simulate the positioner motions with a mounted load or make suitable
calculations to detect collisions or unfavorable center of gravity constellations.
If necessary, take suitable constructive measures to avoid collisions and instability in
the overall system.
Avoid or mark danger zones that result from the installation of the L-402 and the
application, in accordance with the legal regulations.
5.2
Attaching the L-402 to a Surface
NOTICE
Warping of the L-402 due to mounting on uneven surfaces!
Mounting the L-402 on an uneven surface can warp the L-402. Warping reduces the accuracy.
Mount the L-402 onto an even surface. The recommended flatness of the surface is ≤10
µm.
For applications with large temperature changes:
Only mount the L-402 on surfaces that have the same or similar thermal expansion
properties as the L-402.
Requirements
You have read and understood the general notes on installation (p. 11).
You have provided a suitable surface (for the required position and depth of the holes
for accommodating the screws and locating pins, see "Dimensions" (p. 30)):
−
For mounting on the bottom of the L-402: Two M2 threaded holes are provided.
−
For mounting on the front of the L-402: Two M2.5 threaded holes are provided.
−
If you use locating pins to align the L-402: Two 1.5 mm Ø locating holes are present.
−
The flatness of the surface is ≤10 µm.
−
For applications with large temperature changes: The surface should have the same
or similar thermal expansion properties as the L-402 (e.g., surface made of
aluminum).
You have accounted for the space required to route cables without bending and
according to regulations.
Tools and accessories
Mounting accessories; scope of delivery (p 7)
−
2 socket head screws, ISO 14580 M2x6 (when mounting in the bottom) or M2.5x8
(when mounting on the front)