phytron
33
MA 1263-A010 EN
No. Meaning
Default
P30
For I4XM01 only!
Frequency band setting
0 = manual
1 = automatic
Remark
1
:
It is recommended to work with the automatic setting
mode.
For each run frequency (P14) and ramp (P15) the
controller automatically selects suitable settings.
P31
For I4XM01 only!
Frequency and ramp predivider (only if P30 = 0,
manual)
This parameter changes the predivider which supplies
the hardware (frequency generated) with a clock of 20
MHz derived.
3
P31
Run frequency
resolution predivider
0 1 Hz … 8 kHz
⅛ Hz
2440
1 1 Hz … 16 kHz
¼ Hz
1220
2 1 Hz … 32 kHz
½ Hz
609
3 1 Hz … 65 kHz
1 Hz
304
4 2 Hz … 130 kHz
2 Hz
152
5 4 Hz … 260 kHz
4 Hz
75
6 8 Hz … 520 kHz
8 Hz
37
7 16 Hz … 1 MHz
16 Hz
18
8 32 Hz … 2 MHz
32 Hz
9
9 64 Hz … 4 MHz
64 Hz
4
The parameter can be used for individual settings when
automatic frequency band setting for the specific
application is not appropriate.
P32
TBD
1