ProfiNet / ProfiBus interfaces
MA 1263-A010 EN
32
No. Meaning
Default
P26
The data transfer rate is set by P26 (
ONLY
for SSI
encoder), by which the encoder is read. The transfer
rate is dependent on the length of the cable by which
the encoder is connected to the device. The shorter the
cable, the encoder can more quickly be read.
Data transfer rate 1 to 10 (= 100 to 1000 kHz)
1 = 100 kHz
2 = 200 kHz
3 = 300 kHz
4 = 400 kHz
5 = 500 kHz
6 = 600 kHz
7 = 700 kHz
8 = 800 kHz
9 = 900 kHz
10 = 1000 kHz
1
P27
Limit switch type
NCC: normally closed contact
NOC: normally open contact
LIMIT–
Center/Ref
LIMIT+
0
NCC
NCC
NCC
1
NCC
NCC
NOC
2
NOC
NCC
NCC
3
NOC
NCC
NOC
4
NCC
NOC
NCC
5
NCC
NOC
NOC
6
NOC
NOC
NCC
7
NOC
NOC
NOC
0
P28
Axis options
0 = Power stage is deactivated after power on
1 = Power stage is activated after power on
0
P29
not used