5.2 Electrical Installation
Ensure sufficient bending radius of the cables during installation. Do not lay the cables in tension
or bend them.
We recommend labeling the mating connectors to prevent interchanging the connectors.
If all the connections are made, the last step is to plug in the power supply to the mains.
5.2.1 Connectors - Overview
Connector
Number
of pins
Connector on the
module (Phoenix)
Mating connector
(Phoenix)
Mating connector
ID number
INAM01:
Motor (X5)
1x4
IC 2,5/4-G-5,08
IC 2,5/4-ST-5,08
10005390
INAM02:
Motor (X5)
1x4
IC 2,5 HC/ 4-G-5,08
FKIC 2,5 HC/4-ST-
5,08
10015856
Limit switches
(X2)
1x10
MCDN1,5/10-G1-
3,5P26
FMC1,5/10-ST-3,5
10013217
Encoder (X1)
1x10
MCDN1,5/10-G1-
3,5P26
FMC1,5/10-ST-3,5
10013217
Temperature
evaluation
(X3/X4)
2x2
MCDN1,5/2-G1-
3,5P26
FMC1,5/2-ST-3,5
10007077
The mating connector is included in delivery of the module and is usually plugged into the module
at the factory.
i
CAUTION – Possible damage!
Damage of the module by wrong connection.
- Do not exchange the 10-pin connector for limit switches with the
10-pin connector for the encoder evaluation. Module and encoder can be
damaged.
Summary of Contents for phyMOTION INAM01.1
Page 10: ...Manual INAM01 INAM02 MA 1275 A004 EN 10...
Page 11: ...phytron 11 MA 1275 A004 EN 4 2 Declaration of Conformity Modules with Internal Supply INT...
Page 12: ...Manual INAM01 INAM02 MA 1275 A004 EN 12...
Page 25: ...phytron 25 MA 1275 A004 EN Fig 5 PE connection for 5 wire motor cable by the NETM01 module...
Page 34: ...Manual INAM01 INAM02 MA 1275 A004 EN 34...
Page 35: ...phytron 35 MA 1275 A004 EN Synchronisation Fig 7 Synchronisation wiring...