JP38
1+2,3+4
open,open
Power switching, supply from 5 V adapter or POE
No power switching, direct supply from VCC_3V3
JP39
1+2,3+4
open,open
Power switching active, Battery charge path closed
No power switching, direct supply from VCC_3V3
JP40
open
closed
No power switching active, minimum circuit
Power switching active
JP42
1+2
2+3
USB VBUS power enable managed on baseboard
USB VBUS power enable managed on module
JP43
1+2
2+3
USB VBUS overcurrent managed on the baseboard
USB VBUS overcurrent managed on the module
JP44
open
closed
USB Host is managed on the module
USB Host is managed on the baseboard
JP45
1+2
2+3
USB Host is managed on the baseboard
USB Host is managed on the module
JP46
1+2
2+3
USB Host is managed on the baseboard
USB Host is managed on the module
JP47
open
closed
Reset of audio/touch device is not controllable
Reset of audio/touch device is controllable via GPIO
JP48
open
closed
IRQ of audio/touch device is not controllable
IRQ of audio/touch device is controllable via GPIO
JP49
open
closed
PENDOWN of audio/touch device is not controllable
PENDOWN of audio/touch device is controllable via GPIO
JP50
open
closed
SD card write protect is not connected to the module
SD card write protect is connected to the module
JP602
open
closed
PC_RW inverted
PC_RW non-inverted
JP604
open
closed
CF power is manged by x_EXP007
Force enabling VCC_CFL
Summary of Contents for phyCORE-i.MX27
Page 34: ...phyCOREi MX27 26 PHYTEC Messtechnik GmbH 2011 L 710e_5 ...
Page 38: ...phyCOREi MX27 30 PHYTEC Messtechnik GmbH 2011 L 710e_5 ...
Page 52: ...phyCOREi MX27 44 PHYTEC Messtechnik GmbH 2011 L 710e_5 ...
Page 56: ...phyCOREi MX27 48 PHYTEC Messtechnik GmbH 2011 L 710e_5 ...
Page 94: ...phyCOREi MX27 86 PHYTEC Messtechnik GmbH 2011 L 710e_5 ...
Page 100: ...Published by PHYTEC Messtechnik GmbH 2011 Ordering No L 710e_5 Printed in Germany ...