phyCOREi.MX27
82
©
PHYTEC Messtechnik GmbH 2011 L-710e_5
14.3.11
Complete jumper setting list for phyCORE-i.MX27
on the i.MX Carrier Board
The following table contains all jumper settings that can be set on the phyCORE-i.MX Carrier Board. Also it
shows the default jumper settings for using the phyCORE-i.MX27 module with the i.MX Carrier Board.
These default jumper settings are normally done prior to delivery.
Table 32: Jumper settings for i.MX27 module on i.MX Carrier Board
1
J
UMPER
S
ETTING
D
ESCRIPTION
JP1
open
closed
RS-232 transceivers are enabled
RS-232 transceivers are disabled
JP2
open
closed
RS-232 auto shutdown is disabled
RS-232 auto shutdown is enabled
JP3
open
closed
Camera interface is managed by x_CSI_ENABLE
Camera interface is always enabled
JP4
open
closed
Compact Flash is in overwrite mode
Compact Flash is usable
JP5
open
closed
Compact-Flash is Slave
Compact-Flash is Master
JP6
open
closed
USBH2 transceiver Reset is not controllable
USBH2 transceiver Reset is controllable via GPIO
JP7
1+2
2+3
CAN is managed on the Carrier Board
CAN is managed on the module
JP8
1+2
2+3
CAN signals is are on the level VCC_CAN (from mapper)
CAN signals is are on the level VCC_5V
JP9
1+2
2+3
CAN is supplied via on Board 5 V Power-Supply
CAN is supplied via an external Power-Supply
JP10
1+2
2+3
CAN is managed on the Carrier Board
CAN is managed on the module
JP11
1+2
2+3
CAN is supplied via on Board Power-Supply
CAN is supplied via an external Power-Supply
JP12
open
closed
Only the System JTAG Controller
All core's TAPS in a single daisy chain
JP13
open
closed
USB Host transceiver is disabled
USB Host transceiver is enabled
JP14
open
closed
VCC_FUSE = 2.775 V (no FUSE programming)
VCC_FUSE = 3,3V (use only for FUSE programming)
JP15
1+2
2+3
Camera interface supplied via on-board 3.3 V supply
Camera interface is supplied via external supply
JP16
1+2
2+3
CMOS-Sensor I²C address is 0x55
CMOS-Sensor I²C Address is 0x33
JP17
open
closed
Compact Flash expansion connector is enabled
Compact Flash expansion connector is disabled
1
Default settings are in
bold blue
Summary of Contents for phyCORE-i.MX27
Page 34: ...phyCOREi MX27 26 PHYTEC Messtechnik GmbH 2011 L 710e_5 ...
Page 38: ...phyCOREi MX27 30 PHYTEC Messtechnik GmbH 2011 L 710e_5 ...
Page 52: ...phyCOREi MX27 44 PHYTEC Messtechnik GmbH 2011 L 710e_5 ...
Page 56: ...phyCOREi MX27 48 PHYTEC Messtechnik GmbH 2011 L 710e_5 ...
Page 94: ...phyCOREi MX27 86 PHYTEC Messtechnik GmbH 2011 L 710e_5 ...
Page 100: ...Published by PHYTEC Messtechnik GmbH 2011 Ordering No L 710e_5 Printed in Germany ...