background image

8

Rev. IV 2016

9

9

Rev. IV 2016

The device can produce sparks. To avoid them, always use the lowest electrical intensity before putting the electrode on the 
skin. Then increase gradually the intensity. Before removing the electrode from the skin, set the intensity back to its minimum 
and turn off the device.
WARNING! Never insert or remove glass electrodes when the device is on!

TRANSPORTATION AND STORAGE

When transporting the device, avoid shaking it, dropping it and turning it upside down. Store it in a cool, dry place, free of 
any corrosive gas.

CLEANING AND MAINTENANCE

• 

Unplug the device before cleaning.

• 

Use a mild, non-corrosive detergent.

• 

Let the device dry before using it again.

• 

Store the device in a dry, cool location, free from moisture and direct sunlight.

• 

The quartz balls can be washed in a sieve under running water with a mild detergent.

REGULAR CONTROL OF THE DEVICE

Regularly ensure that the device is in good condition. Should it be damaged, please stop using it immediately and contact 
your customer service to solve the problem.
What to do in case of problem?
Please contact your customer service and prepare the following information:

• 

Invoice number and serial number (the latter is to be found on the technical plate on the device).

• 

If relevant, a picture of the damaged, broken or defective part.

• 

It will be easier for your customer service advisor to identify the source of the problem if you give a detailed and 
precise description of the matter

The more details you give, the quicker the customer service will be able to solve your problem!
CAUTION: Never open the device without the authorization of your customer service. This may void the guarantee!

PURPOSE

The HIGH FREQUENCY ELECTROSTIMULATION DEVICE HFI-10 is a cosmetic device used in SPA salons, beauty salons 
or fitness clubs.  It is designed to generate high-frequency therapeutic micro-currents, in order to improve cell metabolism, 
clean and disinfect the skin, enhance microcirculation, improve the absorption of active principles from cosmetics, as well as 
to tone up the skin and reduce wrinkles.
In case of damage resulting from an improper use of the device, the user shall assume all liability.

BEFORE FIRST USE

On receipt of the parcel, make sure the packaging is undamaged before opening it. If the packaging is damaged, please contact 
your transport company and distributor within 3 days. Be as specific as possible when describing the damages. Do not turn 
the package upside down! When transporting the package, please ensure that it is kept horizontal and stable. The packaging 
materials (cardboard, plastic straps, polyurethane foam) should be kept at hand, so that the device can be sent back to the 
service centre, if needed, in the best conditions!

ENVIRONMENT OF USE

The room temperature must not be higher than 45°C and the relative humidity should be under 85%. Keep the device away 
from hot surfaces. Operate the device on flat, stable, clean, refractory and dry surfaces, out of the reach of children and 
people with mental disabilities. Make sure that the power outlet is always within reach. The power outlet must be properly 
grounded and match the technical requirements of the device.

OPERATING PRINCIPLE 

1

2

3

4

5

1. 

main switch 

2. 

„spoon“ electrode – to treat hard to reach areas  

3. 

„mushroom“ electrode – to treat cheeks, forehead, neck, chest, back.  

4. 

“spot” electrode – to treat hard to reach areas

5. 

“comb” electrode – to treat the scalp  

APPLICATION

Before using the device, prepare the skin properly – it should be dry (wet skin may damage the glass electrode).
Remove the device from the box WITH DRY HANDS. Put the switch in the off position.  
Select the appropriate electrode and insert its metal tip in the device output. Please note that both the electrode and your 
hands must be completely dry. 
Turn on the device by rotating the main knob clockwise, until you reach the desired intensity.  Start with the lowest intensity 
- it can be increased gradually by turning the knob clockwise.  Never touch metal objects with the device. Before use, the 
person on whom the treatment is to be performed should remove all metal items (such as jewellery, etc.).  
Place the glass electrode to the skin and adjust electrical intensity.  Please note! It is forbidden to use the electrodes on 
eyelids!  Any treatment around the eyes should be done with extreme caution, only at the lowest intensity. You may want 
to combine the use of this device with skin cosmetics (such as masks): if so, make sure they are oil-based (not water-based) 
and acohol-free. 

1

Summary of Contents for 4103

Page 1: ...ONI PER L USO MANUAL DE INSTRUCCIONES INSTRUKCJA BEDIENUNGSANLEITUNG NAME DES HERSTELLERS EMAKS SPÓŁKA Z OGRANICZONĄ ODPOWIEDZIALNOŚCIĄ SP K ANSCHRIFT DES HERSTELLERS UL DEKORACYJNA 3 65 155 ZIELONA GÓRA PRODUKTNAME HOCHFREQUENZSTAB ELEKTROTHERAPIE MODELL HFI 10 ...

Page 2: ...igt werden 3 Verwenden Sie das Gerät nur für den vorgesehenen Zweck und nur in Innenräumen 4 Im Falle von unsachgemäßem Gebrauch oder falscher Handhabung kann keine Haftung für eventuell auftretende Schäden übernommen werden 5 Prüfen Sie bitte vor dem ersten Gebrauch ob die Art des Stroms und die Netzspannung mit den Angaben auf dem Typenschild übereinstimmen 6 Dieses Gerät ist nicht dafür bestimm...

Page 3: ...t durch Drehen des Hauptschalters im Uhrzeigersinn ein Stellen Sie die Leistung ebenfalls mit dem Drehknopf ein Beginnen Sie mit dem kleinsten Leistungswert Die Erhöhung des Leistungswertes erfolgt durch Drehen des Drehknopfes in die Uhrzeigerrichtung Vermeiden Sie den Kontakt des Gerätes mit Metallgegenständen Legen Sie vor der Behandlung alle Metallgegenstände zum Beispiel Schmuck ab Führen Sie ...

Page 4: ...does not cover damages resulting from improper use or operation 5 Before first use ensure that the voltage and current requirements of the device match the available power supply 6 This device should not be used by persons including children with limited physical sensory or mental aptitude or lacking the necessary experience and or knowledge unless they are supervised by a qualified person or have...

Page 5: ...er shall assume all liability BEFORE FIRST USE On receipt of the parcel make sure the packaging is undamaged before opening it If the packaging is damaged please contact your transport company and distributor within 3 days Be as specific as possible when describing the damages Do not turn the package upside down When transporting the package please ensure that it is kept horizontal and stable The ...

Page 6: ...go z przeznaczeniem 2 Zachowaj instrukcję użytkowania w celu jej późniejszego użycia W razie gdyby urządzenie miało zostać przekazane osobom trzecim to wraz z nim należy przekazać również instrukcję użytkowania 3 Urządzenie należy stosować wyłącznie zgodnie z przeznaczeniem i tylko wewnątrz pomieszczeń 4 W przypadku użytkowania niezgodnego z przeznaczeniem lub nieprawidłowej obsługi wyklucza się o...

Page 7: ...jak jest to tylko możliwe Sformułowania takie jak np urządzenie nie grzeje mogą być dwuznaczne i oznaczają zarówno że urządzenie grzeje za słabo lub w ogóle nie grzeje Są to jednak dwie różne przyczyny usterek Im bardziej szczegółowe są dane tym szybciej można Państwu pomóc UWAGA Nigdy nie wolno otwierać urządzenia bez konsultacji z serwisem klienta Może to prowadzić do utraty gwarancji DANE TECHN...

Page 8: ...lisations futures de l appareil Si l appareil est transmis à une tierce personne il doit impérativement être accompagné de ces instructions d emploi 3 N utilisez cet appareil que pour l usage prescrit et seulement en intérieur 4 Le constructeur décline toute responsabilité en cas de dommages résultant d un usage inapproprié ou d une manipulation non conforme de l appareil 5 Avant la première utili...

Page 9: ...imulateur à hautes fréquences HFI 10 est un appareil cosmétique destiné aux salons de beauté centres de spa et établissements similaires L appareil produit des micro décharges électriques à hautes fréquences qui stimulent efficacement le métabolisme Parmi ses fonctions nettoyage antibactérien de la peau amélioration du métabolisme cellulaire activation de la microcirculation raffermissement de la ...

Page 10: ...e tutte le norme di sicurezza per evitare danni causati da un uso non appropriato del dispositivo 2 Conservare in ogni caso le istruzioni di funzionamento In caso di cessione a terzi l apparecchio deve essere consegnato insieme al suo libretto di istruzioni 3 Utilizzare l apparecchio soltanto per l uso previsto e solo nei luoghi chiusi 4 In caso di uso improprio e inadeguato la garanzia non copre ...

Page 11: ...senza l autorizzazione del servizio clienti Questa operazione non autorizzata fa decadere la garanzia Dati tecnici Nome del prodotto Bacchetta ad alta frequenza per elettroterapia Modello HFI 10 Articolo numero 4103 Tensione nominale V frequenza Hz 230 50 Potenza W 10 CAMPO DI APPLICAZIONE La bacchetta ad alta frequenza per elettroterapia HFI 10 è un dispositivo cosmetico ideale per spa studi di e...

Page 12: ...ste manual debe ser entregado a toda persona que vaya a hacer uso del dispositivo 3 Utilice el equipo solo para los fines previstos y únicamente en espacios interiores 4 No nos hacemos responsables de los daños ocasionados por un uso indebido o un manejo incorrecto del dispositivo 5 Antes del primer uso compruebe si el tipo de suministro eléctrico y el voltaje coinciden con los datos indicados en ...

Page 13: ...es de belleza o instalaciones similares El equipo genera microcorriente de alta frecuencia que actúan positivamente sobre el metabolismo Además desinfecta la piel elimina bacterias mejora el funcionamiento de las células y de la microcirculación epidérmicas aumenta la tersura y reduce las arrugas El usuario es el responsable único de los daños derivados de un uso inadecuado del aparato ANTES DEL P...

Page 14: ...powiedzialnością sp k MANUFACTURER ADDRESS ul Dekoracyjna 3 65 155 Zielona Góra DESIGNED IN GERMANY ASSEMBLED IN PRC NAZWA PRODUKTU PRZYRZĄD WYSOKIEJ CZĘSTOTLIWOŚCI MODEL HFI 10 NAPIĘCIE 230 V 10 CZĘSTOTLIWOŚĆ 50 HZ MOC 10 W KLASA II NAZWA PRODUCENTA emaks spółka z ograniczoną odpowiedzialnością sp k ADRES PRODUCENTA ul Dekoracyjna 3 65 155 Zielona Góra ZAPROJEKTOWANOWNIEMCZECH WYPRODUKOWANOWPRC F...

Page 15: ...ehenden Möglichkeiten der Rückgabe oder Sammlung von Altgeräten 1 RICHTLINIE 2002 96 EG DES EUROPÄISCHEN PARLAMENTS UND DES RATES ÜBER ELEKTRO UND ELEKTRONIK ALTGERÄTE 2 Gesetz über das Inverkehrbringen die Rücknahme und die umweltverträgliche Entsorgung von Elektro und Elektronikgeräten Elektro und Elektronikgerätegesetz ElektroG Umwelt und Entsorgungshinweise CONTACT emaks spółka z ograniczoną o...

Reviews: