9 Pixel Data Processing
9.4.2
Gamma
The ’Gamma’ mode performs an exponential amplification, configurable in the range from 0.4
to 4.0. Gamma > 1.0 results in an attenuation of the image (see Fig. 9.10), gamma < 1.0 results
in an amplification (see Fig. 9.11). Gamma correction is often used for tone mapping and
better display of results on monitor screens.
0
200
400
600
800
1000
1200
0
50
100
150
200
250
300
Grey level transformation − Gamma: y = (255 / 1023
γ
)
⋅
x
γ
(
γ
≥
1)
x: grey level input value (10 bit) [DN]
y: grey level output value (8 bit) [DN]
γ
= 1.0
γ
= 1.2
γ
= 1.5
γ
= 1.8
γ
= 2.5
γ
= 4.0
Figure 9.10: Applying gamma correction to an image (gamma > 1)
0
200
400
600
800
1000
1200
0
50
100
150
200
250
300
Grey level transformation − Gamma: y = (255 / 1023
γ
)
⋅
x
γ
(
γ
≤
1)
x: grey level input value (10 bit) [DN]
y: grey level output value (8 bit) [DN]
γ
= 1.0
γ
= 0.9
γ
= 0.8
γ
= 0.6
γ
= 0.4
Figure 9.11: Applying gamma correction to an image (gamma < 1)
64 of 121
MAN076 09/2017 V1.0
Summary of Contents for MV3-D640I-M01-144-CL
Page 10: ...1 Preface 10 of 121 MAN076 09 2017 V1 0...
Page 34: ...4 Image Acquisition 34 of 121 MAN076 09 2017 V1 0...
Page 46: ...6 I O Control 46 of 121 MAN076 09 2017 V1 0...
Page 76: ...9 Pixel Data Processing 76 of 121 MAN076 09 2017 V1 0...
Page 78: ...10 Thermoelectric Cooler TEC 78 of 121 MAN076 09 2017 V1 0...
Page 82: ...11 Precautions 82 of 121 MAN076 09 2017 V1 0...
Page 94: ...12 Hardware Interface 94 of 121 MAN076 09 2017 V1 0...
Page 100: ...14 Troubleshooting 100 of 121 MAN076 09 2017 V1 0...
Page 106: ...17 Support and Repair 106 of 121 MAN076 09 2017 V1 0...
Page 108: ...18 References 108 of 121 MAN076 09 2017 V1 0...
Page 112: ...A Pinouts 112 of 121 MAN076 09 2017 V1 0...