5
Counter & Timer
5.1
Counter
C
o u n t e r
S
o
u
r
c
e
.
.
.
A c t i v a t i o n
R
i s i n g E d g e
F a l l i n g E d g e
B o t h E d g e s
S
o
u
r
c
e
.
.
.
A c t i v a t i o n
R i s i n g E d g e
F a l l i n g E d g e
B o t h E d g e s
S
o
u
r
c
e
.
.
.
A c t i v a t i o n
R i s i n g E d g e
F a l l i n g E d g e
B o t h E d g e s
C o u n t e r
T r i g g e r
C o u n t e r
E v e n t
C o u n t e r
R e s e t
T i m e S t a m p
T i c k
C o u n t e r D u r a t i o n
C o u n t e r S t a r t V a l u e
C o u n t e r V a l u e
C o u n t e r S t a t u s
C o u n t e r R e s e t ( )
C o u n t e r V a l u e A t R e s e t
C o u n t e r A c t i v e
C o u n t e r S t a r t
C o u n t e r E n d
Figure 5.1: Counter Structure
Four general purpose counters are available (Counter0 . . . Counter3) which are used for
counting events. Each counter can be individually configured by software and controlled by
counter trigger, counter event and counter reset signals. This section describes the
configuration and the function of the counters.
Fig. 5.1 shows the structure of one counter. Along with the counter function itself it contains a
counter trigger source, a counter event source and a counter reset source selection and
activation block. Furthermore there is a counter active status signal, which is available in the
I/O control block (see Chapter 6). And the counter generates counter start and counter end
events, which can be used to trigger other blocks, like counter, timer, acquisition, frame or
exposure control.
5.1.1
Counter Usage
In a basic usage, at least a counter event source needs to be selected (see Section 5.1.5 for more
information about the counter event source selection). Once an event source has been
selected, the counter needs to be reset in order to start the counter. When started it counts
from a defined start value, which is configurable by the CounterStartValue property, and ends
counting events after a certain number of events, which is configurable by the
CounterDuration property.
MAN076 09/2017 V1.0
35 of 121
Summary of Contents for MV3-D640I-M01-144-CL
Page 10: ...1 Preface 10 of 121 MAN076 09 2017 V1 0...
Page 34: ...4 Image Acquisition 34 of 121 MAN076 09 2017 V1 0...
Page 46: ...6 I O Control 46 of 121 MAN076 09 2017 V1 0...
Page 76: ...9 Pixel Data Processing 76 of 121 MAN076 09 2017 V1 0...
Page 78: ...10 Thermoelectric Cooler TEC 78 of 121 MAN076 09 2017 V1 0...
Page 82: ...11 Precautions 82 of 121 MAN076 09 2017 V1 0...
Page 94: ...12 Hardware Interface 94 of 121 MAN076 09 2017 V1 0...
Page 100: ...14 Troubleshooting 100 of 121 MAN076 09 2017 V1 0...
Page 106: ...17 Support and Repair 106 of 121 MAN076 09 2017 V1 0...
Page 108: ...18 References 108 of 121 MAN076 09 2017 V1 0...
Page 112: ...A Pinouts 112 of 121 MAN076 09 2017 V1 0...