C Use Cases
1.
The
TriggerMode
of
FrameStart
trigger must be set to
On
. The
AcquisitionStart
,
FrameBurstStart
and the
ExposureStart
must be set to
Off
.
2.
The
TriggerSource
of the
FrameStart
trigger must be set to the corresponding source. For
instances to
Line0
.
3.
Since the source is set to
Line0
, the
TriggerActivation
must be set accordingly:
RisingEdge
,
FallingEdge
or
AnyEdge
.
4.
TriggerDelay
and
TriggerDivider
of the
FrameStart
trigger must be set accordingly.
5.
The required image
Width
and
Height
must be set.
6.
The required
PixelFormat
must be set.
7.
AcquisitionMode
must be set to
Continuous
.
8.
The software command
AcquisitionStart()
must be applied.
After these configurations, the camera is waiting for a frame start trigger.
It might be necessary to adjust the polarity of the
Line0
input signal. This can be done by the
parameter
LineInvert
in the section DigitalIOControl.
C.1.4
Camera runs in burst triggered mode
If a certain number of images must be acquired on a single trigger input event, the cameras
frame burst start trigger feature can be used. The following configuration procedure shows
how to set the camera in burst triggered mode:
1.
The
TriggerMode
of
FrameBurstStart
trigger must be set to
On
. The
AcquisitionStart
,
FrameStart
and the
ExposureStart
trigger must be set to
Off
.
2.
The
TriggerSource
of the
FrameBurstStart
trigger must be set to the corresponding source.
For instances to
Line0
.
3.
Since the source is set to
Line0
, the
TriggerActivation
must be set accordingly:
RisingEdge
,
FallingEdge
or
AnyEdge
.
4.
TriggerDelay
and
TriggerDivider
of the
FrameBurstStart
trigger must be set accordingly.
5.
The number of frame within a burst must be set by parameter
AcquisitionBurstFrameCount
parameter.
6.
The required image
Width
and
Height
must be set.
7.
The required
PixelFormat
must be set.
8.
AcquisitionMode
must be set to
Continuous
.
9.
The software command
AcquisitionStart()
must be applied.
It might be necessary to adjust the polarity of the
Line0
input signal. This can be done by the
parameter
LineInvert
in the section DigitalIOControl.
C.1.5
Triggered controlled exposure mode
The exposure time can be controlled by an externally applied trigger signal on LineIn input.
The following configuration procedure shows how to set the camera in the triggered
controlled exposure mode:
1.
Parameter
ExposureMode
must be set to
TriggerControlled
.
2.
The TriggerMode of
ExposureStart
and
ExposureEnd
trigger must be set to
On
. The
AcquisitionStart
,
FrameStart
and
FrameBurstStart
trigger must be set to
Off
.
116 of 121
MAN076 09/2017 V1.0
Summary of Contents for MV3-D640I-M01-144-CL
Page 10: ...1 Preface 10 of 121 MAN076 09 2017 V1 0...
Page 34: ...4 Image Acquisition 34 of 121 MAN076 09 2017 V1 0...
Page 46: ...6 I O Control 46 of 121 MAN076 09 2017 V1 0...
Page 76: ...9 Pixel Data Processing 76 of 121 MAN076 09 2017 V1 0...
Page 78: ...10 Thermoelectric Cooler TEC 78 of 121 MAN076 09 2017 V1 0...
Page 82: ...11 Precautions 82 of 121 MAN076 09 2017 V1 0...
Page 94: ...12 Hardware Interface 94 of 121 MAN076 09 2017 V1 0...
Page 100: ...14 Troubleshooting 100 of 121 MAN076 09 2017 V1 0...
Page 106: ...17 Support and Repair 106 of 121 MAN076 09 2017 V1 0...
Page 108: ...18 References 108 of 121 MAN076 09 2017 V1 0...
Page 112: ...A Pinouts 112 of 121 MAN076 09 2017 V1 0...