BATTERY OK
: When on steadily this LED indicates that the external bat-
tery is fully charged. When blinking it indicates that the battery is low. When
off it indicates that the battery is either not connected or very low.
PHONE Status
: This LED indicates if the SCADA 3000 is currently using
the phone line.
14.
Input Terminal Strip
: These terminals are for connecting input sensors and
transducers. The upper row is the positive input and the lower row is the
negative input. The inputs are differential for certain jumper configurations so
be sure to wire them in direct vertical pairs (eg. The positive input wire directly
above the negative input wire).
15.
Input Configuration Jumpers
: These jumpers are used to condition the
input for different types of sensors. Use needlenose pliers to move them to the
appropriate position. (See Chapter 5: Input Wiring)
16.
Voice Port
: This jack is for plugging in a telephone to listen to a status report
or record messages if the voice option is installed.
17.
Phone Line
: This is the jack for connecting to the telephone network.
18.
Phone Extension
: This jack is for connecting telephone extensions to the
same line as the SCADA 3000. This jack features Line Seizure so that if the
SCADA 3000 needs to make a call it will disconnect the extensions and seize
the line for its own use.
19.
Expansion Bus Terminal Strip
: This terminal strip is for connecting the
4-wire communications link to the I/O expansion modules.
20.
Bus Termination
: This jumper selects whether the expansion bus is termi-
nated or not.
21.
Spare Fuses
: Spare fuses are provided for the main power, 24V supply, aux
supply and battery.
About I/Os and modules
The SCADA 3000 comes with 16 universal inputs and 8 relay outputs. Additional inputs and
outputs may be added by connecting additional I/O modules to the main unit. Up to 15 mod-
ules may be connected to the unit providing as many as 144 total I/O points. The modules
connect to the unit via a 4-wire communications bus. They may be located up to 2000 feet
away from the main unit. Modules are available to connect a variety of I/O devices:
FGD-3010
Scada 3000 8 Channel Universal Input Module
FGD-3020
Scada 3000 4 Channel Pulse Count Input Module
FGD-3040
Scada 3000 8 Channel Relay Output Module
FGD-3050
Scada 3000 4 Channel Analog Output Module
FGD-3060
Scada 3000 8 Channel Annunciator Module
1-4
SCADA 3000 User’s Manual
Summary of Contents for Sensaphone SCADA 3000
Page 1: ...Sensaphone SCADA 3000 User s Manual Version 2 34...
Page 6: ...vi SCADA 3000 User s Manual...
Page 10: ...x SCADA 3000 User s Manual...
Page 30: ...1 6 SCADA 3000 User s Manual...
Page 48: ...4 6 SCADA 3000 User s Manual...
Page 70: ...9 8 SCADA 3000 User s Manual...
Page 122: ...12 8 SCADA 3000 User s Manual...
Page 190: ...15 30 SCADA 3000 User s Manual...
Page 211: ...lead 1 lag 0 else lead 0 lag 1 16 21 Chapter 16 Programming in C...
Page 212: ...16 22 SCADA 3000 User s Manual...
Page 236: ...21 8 SCADA 3000 User s Manual...
Page 248: ...22 12 SCADA 3000 User s Manual...
Page 258: ...23 10 SCADA 3000 User s Manual...
Page 274: ...25 8 SCADA 3000 User s Manual...
Page 288: ...27 8 SCADA 3000 User s Manual...
Page 294: ...28 6 SCADA 3000 User s Manual...
Page 296: ...A 2 SCADA 3000 User s Manual...
Page 302: ...D 2 SCADA 3000 User s Manual...
Page 318: ...I 2 SCADA 3000 User s Manual...
Page 320: ...J 2 SCADA 3000 User s Manual...
Page 322: ...K 2 SCADA 3000 User s Manual...
Page 335: ...Test Log...
Page 336: ......