116
Phoenix RPC12 Series CLI Reference Manual • September 2008
set host-parameters
Description
Sets the link speed and topology for host channels on specified controllers. The new
settings take effect without restarting the RAID controllers.
Input
set host-parameters [controller a|b|both] [speed
speed
] [channel
#
|all][fibre-connection-mode loop|point-to-point] [IP
address
]
[netmask
address
] [gateway
address
] [noprompt]
Parameter
Description
controller a|b|both
Optional. Specifies whether to apply the settings to
controller A (upper), controller B (lower), or both.
Required if either
speed
or
fibre-
connection-mode
is specified.
speed
speed
Optional. Sets the link speed in Gbit/sec, which
automatically changes for the partner host channel
on the other controller. Valid values for FC: 2g, 4g.
Valid values for iSCSI: 10mb, 100mb, 1g. If you
change a parameter on controller A channel 0, then
controller B channel 1 also changes. The same is
true for A1 and B0.
channel
#
|all
Optional. Specifies a host channel number. If this
parameter is omitted, all host channels on the
specified controllers are affected.
fibre-connection-mode
loop|point-to-point
Optional. FC only. Sets the topology for the
specified channels on the specified controllers to
either:
•
loop
: Fibre Channel-Arbitrated Loop (public or
private).
•
point-to-point
: Fibre Channel point-to-
point. Point-to-point topology is only valid and
allowed when port interconnects are disabled
(using
set host-port-interconnects
).
IP
address
Optional. iSCSI only. Specifies the IP address for
an iSCSI port in IPv4 format.
Summary of Contents for RPC12 Series
Page 1: ......
Page 11: ...12 Phoenix RPC12 Series CLI Reference Manual September 2008...
Page 29: ...30 Phoenix RPC12 Series CLI Reference Manual September 2008...
Page 35: ...36 Phoenix RPC12 Series CLI Reference Manual September 2008...
Page 227: ...228 Phoenix RPC12 Series CLI Reference Manual September 2008...