Page 10 of 124
1
2.3
COMMAND LINE INTERFACE
2
Via the command line interface the execution of diagnostic nuclei can be controlled.
3
4
2.3.1 Set-up of physical interface components
5
Hardware required:
6
•
Control PC
7
•
One free COM port on the Control PC
8
•
Special cable to connect the DVD Recorder to the Control PC
9
The control PC must use the following port settings for the used COM port:
10
- 19200
bps,
11
- 8
data bits,
12
- n
o parity,
13
- 1
stop bit and
14
- no flow
control.
15
The control PC is connected with a special cable (see chapter 4A.2) to the RS232 port of the
16
DVD Recorder. Via the same connection the ‘test pin’ will be connected to ground. Using this
17
pin the software can determine whether Diagnostic mode needs to be entered.
18
19
2.3.2 Activation
20
After power on the next text will be sent to the control PC
21
22
Factory Diagnostics and Service Software
23
DVD Video Recorder (Dec 13 2003, 10:55:37)
24
25
Version :258 Build :20031213_1030
26
Release :P1_7_b Buildtype :no
27
Baseline :I_P1_8_63 Variant :verum:dvdrw2_lib
28
29
DS:>
30
31
The first lines indicate that the DSW has been activated and contains the version and build info
32
of the DSW. The next line is the command line prompt (“
DS:>
”). The DSW is now ready to
33
receive commands. Please note that this text will be different on your specific variant of the
34
DVD+RW recorder product range.
35
36
2.3.3 Usage
37
The commands that can be given are the numbers of the nuclei. A command must be
38
terminated with an <ENTER> character from the control PC. When typing commands, the
39
backspace key can be used to make corrections. Apart from this one can use the Up and Down
40
arrows to browse to previous commands.
41
When one enters non-supported commands, the interface returns the command line prompt.
42
43
If the command (the nucleus number) is recognised, the nucleus is executed. Result and output
44
of an activated (and terminated) nucleus will be sent back to the control PC.
45
46
Example in case the command is correct:
47
48
DS:> 1200
49
Summary of Contents for DVDR3575H/
Page 152: ...Front Board Waveforms Emitter 7106 7108 2140 I102 1110 I103 1110 ...
Page 153: ...Layout Front Board Bottom View Front Board Bot View 3139 243 36464_sh132_a4 eps 2007 07 11 ...
Page 155: ...Layout Front Board Top View Front Board Top View 3139 243 36464_sh132_a4 eps 2007 07 11 ...
Page 156: ......
Page 157: ......
Page 158: ......
Page 159: ......
Page 164: ...Layout Analog Bottom View Analog Bottom 3139 243 37473_sh132_a3 eps 2007 07 11 ...
Page 166: ...Layout Analog Top View Analog Top 3139 243 37473_sh132_a3 eps 2007 07 11 ...
Page 172: ... 1 LUFXLW LDJUDPV DQG 3 D RXWV D RXW LJLWDO 7RS 9LHZ ...
Page 182: ... 1 D RXW LJLWDO RWWRP 9LHZ LUFXLW LDJUDPV DQG 3 D RXWV ...
Page 187: ...Layout HDMI Bottom View HDMI Bot View 3139 243 36753_sh132_a4 eps 2007 07 11 ...
Page 189: ...Layout HDMI Bottom View HDMI Top View 3139 243 36753_sh132_a4 eps 2007 07 11 ...