Reference : SGP_AVS_SW_ATLAS-05-05
Classification :
COMPANY
RESTRICTED
Version :
0.17
Project
:
ATLAS_DSW
Status :
Proposed
Chapter
:
User
Manual
Date :
2006-09-12
Section
:
Diagnostic Software (Leco+)
© Philips Electronics N.V. 2006
Philips Semiconductors
Page 106 of 124
Nucleus Name
DS_DTTM_IicRead
Nucleus Number
2217
Description
Performs an IIC read action on the DTT module.
Technical
-
Send DTTM command ID 2901 with the supplied parameters, separated by
a single space character.
Execution Time
< 1 sec.
User Input
1. IicChannel : IIC channel of the device
2. IicDeviceAddress : address of IIC device to read from
3. NrOfSubAddressBytes: number of sub-address bytes (=x)
4. SubAddressBytes : x sub-address bytes
5. NrOfValues : number of values to read (=y)
Error Number
Description
221700
The test was successful
221701
Insufficient number of input data supplied
221702
No response from the given device-address
221703
Incorrect device address was given
221704
Unable to send IIC start-condition
221705
Error during read from IIC-address
221706
Device does not support IIC read
221707
The IIC read action failed.
221708
Communication with the DTT Module failed.
221709
DTT Module initialisation failed.
Example
DS:> 2217 0x00 0x10 2 0x00 0x00 2
221700: Read values: 0x17 0x00
Test OK @
1
Nucleus Name
DS_DTTM_AvTsPidSet
Nucleus Number
2218
Description
Sets the PID values of the transport stream.
Technical
-
Send the DTTM command ID 1503, with the supplied parameters.
Execution Time
< 1 sec.
User Input
1. Video PID value [0x0000-0x1FFF]
2. Audio PID value [0x0000-0x1FFF]
3. PRC PID value [0x0000-0x1FFF]
Error Number
Description
221800
The TS PID's are set successfully
221801
Insufficient number of input data supplied
221802
One or more PID values is out of range
221803
The TS PID's could not be set.
221804
Communication with the DTT Module failed
221805
DTT Module initialisation failed.
Example
DS:> 2218 0x79 0x7a 0x79
221800:
Test OK @
2
Nucleus Name
DS_DTTM_AvMojoBeepOn
Nucleus Number
2219
Description
Generates the Mojo beep.
Technical
-
Send the DTTM command ID 1605.
Execution Time
< 1 sec.
User Input
None
Error Number
Description
221900
The Mojo beep has been turned on successfully
221901
Can not start another AV test (one is already running)
221902
The Mojo beep could not be turned on
221903
Communication with the DTT Module failed
221904
DTT Module initialisation failed.
Example
DS:> 2219
221900:
Test OK @
3
Summary of Contents for DVDR3575H/
Page 152: ...Front Board Waveforms Emitter 7106 7108 2140 I102 1110 I103 1110 ...
Page 153: ...Layout Front Board Bottom View Front Board Bot View 3139 243 36464_sh132_a4 eps 2007 07 11 ...
Page 155: ...Layout Front Board Top View Front Board Top View 3139 243 36464_sh132_a4 eps 2007 07 11 ...
Page 156: ......
Page 157: ......
Page 158: ......
Page 159: ......
Page 164: ...Layout Analog Bottom View Analog Bottom 3139 243 37473_sh132_a3 eps 2007 07 11 ...
Page 166: ...Layout Analog Top View Analog Top 3139 243 37473_sh132_a3 eps 2007 07 11 ...
Page 172: ... 1 LUFXLW LDJUDPV DQG 3 D RXWV D RXW LJLWDO 7RS 9LHZ ...
Page 182: ... 1 D RXW LJLWDO RWWRP 9LHZ LUFXLW LDJUDPV DQG 3 D RXWV ...
Page 187: ...Layout HDMI Bottom View HDMI Bot View 3139 243 36753_sh132_a4 eps 2007 07 11 ...